Explosion Proof Thermal Cycling Chamber ESS-408S
Explosion Proof Thermal Cycling Chamber ESS-408S
- UN ECE R100/UN 38.3/UL 1642/UL 2580
- Battery thermal cycling test chamber
- Explosion proof device
- Temperature cycle test
- ESS Testing
- Balanced temperature and humidity control method (BTHC)
- Robust design & Reliable performance
- Color touch screen
- Mobile casters
- Accept customization
Explosion proof thermal cycling chamber is a customized environmental chamber with a double layer design and two test zones with separate temperature control. This double-layer chamber is specially designed for rapid rate temperature cycle test and can also be customized as temperature test chamber, temperature and humidity test chamber, etc.
Features of Explosion Proof Thermal Cycling Chamber
- Explosion-proof pressure relief port: when the pressure exceeds the set value, the explosion-proof door will open automatically to unload the pressure inside the chamber to prevent damage to the equipment.
- Explosion-proof chain: both sides of the door are equipped with explosion-proof chain.
- Fire extinguishing device: 9L foam extinguisher, 1230 gas fire extinguisher.
- Gas detection device: detection of H2, CO gas.
- Safety protection device: various over-current and overload protection.
Standards of Explosion Proof Thermal Cycling Chamber
UN ECE Regulation No. 100
UN 38.3 38.3 Standards for shipping lithium batteries, either alone or as part of a device
UL 1642 Standard for Lithium Batteries
UL 2580 General guidelines for batteries in electric vehicles
GB/T 2423.1-2008 (IEC68-2-1) Test A: Low temperature test method
GB/T 2423.2-2008 (IEC68-2-2) Test B: High temperature test method
GJB 360.8-2009(MIL-STD.202F)High temperature life test
GJB 150.3-2009 (MIL-STD-810D) High temperature test method
…
Model Number | ESS-408S |
Volume | 408L |
Heating(Cooling) Rate | 5℃/min |
Temperature Range | -40℃~+85℃ |
Temperature Fluctuation | ±0.5℃ |
Temperature Uniformity | ≤1.5℃ |
Temperature Deviation | ≤±1.5℃ |
Humidity Range | 20%~98% R.H |
Humidity Fluctuation | ±2% RH |
Humidity Uniformity | ±3% RH (no load) |
Humidity Deviation | ±3.0%RH(>75%RH)±5.0%RH(≤75%RH) |
Inner Size (single zone) | 850×600×800mm (W×H×D) |
Observation Windows | 300×350mm |
Noise | ≤75dB |
Power | 20KW |
Cooling Method | Air-cooled |
Heating(Cooling)Method | Linear and Non-linear Optional |
GET A QUOTE